RP-ANCHOR.5x3.8-HIL is a 1/2" x 3-3/4" concrete floor anchor for our industry-leading SK3000 Pallet Racking.
ANCHORING NOTES:
- Every column of each rack upright frame must be anchored to an adequate concrete floor.
- This is the normal anchor connection, a 1/2" diameter x 3-3/4" concrete expansion anchor per column footpad, or as indicated on installation drawings.
- Seismic uprights, those with 5” x 7” base plates, utilize (2) 1/2" diameter x 4- 1/2" I.C.C. approved concrete expansion anchors per column footpad.
- Anchor bolts are not included with rack systems unless otherwise noted.
- Since anchor bolts vary in strength, if you are purchasing your own anchor bolts, contact us for minimum anchor specifications for your installation.
- Since concrete floors vary greatly in design and load carrying capacity, we cannot guarantee that a particular concrete slab is adequate to support a particular rack installation. The characteristics of the slab should be obtained from the building architect or engineer before the racks are specified, so that the rack supplier can design the rack to suit the slab.
*Anchoring Note: The use of handheld and stand-mounted drills, impact and rotary hammer drills, and similar tools used to drill holes in concrete, masonry, or other silica containing materials can generate respirable crystalline silica dust. Read this OSHA Fact Sheet to learn how to minimize the amount of airborne dust when using handheld and stand-mounted drills.
https://www.osha.gov/sites/default/files/publications/OSHA_FS-3630.pdf
-
Series
- SK3000 Assembly Manual
- Pallet Rack User & Safety Manual
- SK3000 Product Overview Brochure
- SK3000 Capacity Charts
- SK3000 Test Report Frontal Resistance
- SK3000 Test Report Horizontal Braces
- Warranty
*Notes to Upright Capacities:
- Capacity is based on 36" vertical beam spacing; larger spacing will decrease capacity.
- Capacities based upon interior usage.
- Capacities are for selective rack only.
- Capacities are for non-seismic usage; contact us for seismic requirements.
- All columns and posts must be properly anchored (anchors sold separately) to an adequate concrete floor (required by RMI code)
- Capacities based upon plumb and proper installation.
- Capacities are total per upright, assuming equal loading on both posts.
- For any outdoor storage, stainless steel anchors are required.
If any of these conditions do not apply to your application, or you are unsure, do not use these capacities and consult our engineering department to ensure proper specification and application requirements are met. A permit and/or stamped calculations may also be required by your local building department prior to installation and is the responsibility of the end user. Contact us for any seismic location requirements prior to ordering.